beautypg.com

Great Plains YP4425A Operator Manual User Manual

Page 91

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

87

2012-02-23

Table of Contents

Index

401-805M

Overall High
Population,
cont.

Speed sensor angle.

With planter lowered, check radar speed sensor angle per
DICKEY-john

®

recommendations.

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor

manual.

Overlapping passes

Check marker extension (page 150).
For GPS, check planter size programmed.

Actual field size is different

Population may be correct, and calculations are not.

High
Population,
Single Row

Excess meter pressurization causing
doubles

Check shutter.

Worn seed-drop brush and/or strip
brushes allowing excess seed to
pass

Replace worn brushes.

Incorrect seed disc with higher cell
count.

Install correct disc.

Population Too High

Problem

Cause

Solution

Population Related

Problem

Cause

Solution

Overall
Population
Alarms

False alarms or actual rate errors
due to monitor setup with
incorrect [active] row count or
spacing

When troubleshooting population issues, always first rule out
seed monitor setup. Review planter configuration and monitor
setup.

Incorrect cell count

Replace seed discs with correct discs, or reset rate for current
discs (if within range).

Improper gap on speed sensor.

Check speed sensor on planter for

1

16

in to

1

8

in (1.6-3.2mm)

gap from wheel. Improper gap can cause erratic speed signal
causing monitor to falsely report improper planting rate.

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor

manual.

Mismatch
Between
Reported and
Furrow
Population

Small seeds (example milo) are
not reliably sensed in the seed
tube

Run with rain covers in place to minimize ambient light
intrusion. Use the population adjustment factor in the
DICKEY-john

®

monitor system to compensate for missed

seeds. For example, change the DICKEY-john

®

Population

Adjustment values from 100% to 130% or 140% as needed.
Remember to set this back to 100% for large seeds.

Seed tube sensor is not counting
all seeds

Clean the seed tube of graphite and dust buildup with long
narrow seed tube brush. Replace sensors that malfunction.

Seeds / revolution value in the
DICKEY-john

®

setup does not

match the disc cell count.

Correct the value in a setup screen or install the correct cell
count disc.

Excessive
Seed
Cracking

Incorrect seed pocket size

Use correct disc for seed.

Damaged, old or dried-out seed

Use new seed.

Unclean seed

Use clean seed.