Low
Population,
Single
Row, cont.

Skips due to low meter pressurization at one
or several rows

Check shutter setting.
Check for excess wear on seed drop brush.
Check for loose or leaking pressure hose.

Skips due to skipping chain

Check for worn chain, worn idlers, and low chain slack
(page 107).

Skips due to debris in disc pockets

Remove rain covers. Inspect and clean out discs.

Row has blank disc installed

Replace with seeding disc.

Seed sensor obscured

Clean out seed tube (see page 96).

Seed tube plugged

Raise planter, expose bottom of seed tube and clean
out.

Population Too Low

Problem

Cause

Solution

Population Too High

Problem

Cause

Solution

Overall High
Population

Incorrect seed rate

Check seed rate charts

Two seeds per pocket on the disc
(doubles), due to excess meter
pressurization

Methodically decrease the controlled air to the meter. See
Fan and Adjustment” on page 60.

Two seeds per pocket on the disc
(doubles), due to pockets too large
for the seed

Select a disc with smaller pockets.

Air meter pressure too high due to
pressure sensor not zeroed properly.

Re-zero the air pressure with the fan off. Make sure the
displayed pressure reads 0.00.

Air pressure too high, false
information driving the
DICKEY-john

®

software.

Compare the air pressure reported on the monitor console to
the mechanical gage. If they do not match:
• Inspect the

1

4

inch sampling lines from the row units up to

the sensor chamber for leaks.

• Re-zero the air pressure with the fan off.

False alarms or actual seed rate
errors due to monitor setup with
incorrect row count, spacing or
active rows

When troubleshooting population issues, always first rule out
seed monitor setup. Review planter configuration and
monitor setup.

Incorrect cell count

Replace seed discs with correct discs, or reset rate for
current discs (if within range).

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor

manual. See page 151.

Doubles due to incorrect disc for
crop or seed size

Use recommended disc for crop and seed size.

Sticky seeds: excess seed treatment Increase seed lubricant.