Setting material rates, Planting rate, Fertilizer rate – Great Plains YP4425A Operator Manual User Manual
Page 61: Planting rate fertilizer rate

Great Plains Manufacturing, Inc.
Adjustments
57
2012-02-23
401-805M
Setting Material Rates
Planting Rate
Adjusting the planting rate requires the following:
1.
Monitor configuration:
The seed monitor must be set up with the correct
row count, row spacing and disc cell count. See the
Seed Rate Manual (SRM) and the DICKEY-john
®
Planter/Drill Control (PDC).
2.
Preparing rows:
Correct seed disc selection and Y-tube settings are
required for correct rate. Meter shutter setting and
meter pressurization adjustments assure the rate.
See the SRM.
3.
Ground speed calibration:
Seed monitor rate control and reporting is only as
accurate as the speed reported by the radar. See the
PDC manual.
4.
Setting seed rate via seed monitor:
See the SRM and the PDC manuals.
5.
Checking planting rate:
Although the seed monitor reports a computed
population based on seeds sensed, only an actual
furrow check provides certainty about the actual
seeding rate. See the SRM.
Fertilizer Rate
See page 63 for further detail. The following is a brief
summary of steps:
1.
Pump setting dial and sprockets.
2.
Row orifice setup.
3.
Relief valve setting.
4.
Strainer setup.
Figure 62
Seed Monitor Rate Screen
29772
Figure 63
JohnBlue Fertilizer Pump
26155