beautypg.com

Great Plains YP4425A Operator Manual User Manual

Page 89

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

85

2012-02-23

Table of Contents

Index

401-805M

Overall
Low
Population
(cont.)

Air pressure too low, false information
driving the DICKEY-john

®

software.

Compare the air pressure reported on the monitor
console to the mechanical gage. If they do not match:
• Inspect the

1

4

inch sampling lines from the row units

up to the sensor chamber for leaks.

• Re-zero the air pressure with the fan off.

Low fan speed: meter starvation due to
meter pressurization, leaving insufficient air
for seed delivery

Increase fan speed.

Excess field speed

Plant within speed ranges recommended in seed rate
charts.

Incorrect speed sensor constant.

Perform speed radar calibration per DICKEY-john

®

monitor manual. See page 151.

Speed sensor angle.

With planter lowered, check radar speed sensor angle
per DICKEY-john

®®

recommendations.

Pass gaps too large

Check marker extension (page 150).
For GPS, check planter size programmed.

Actual field size is different

Population may be correct, and calculations are not.

Low
Population,
One
Section

Clutch slipping, due to contaminants in
clutch, or wear

Lock-up clutch (page 44) until it can be overhauled or
replaced

Skipping chain from drive to section

Check chain slack.
Replace worn chain.

Low
Population,
Single Row

Shutter opening too wide - interfering with
meter pressurization

Adjust shutter to lower setting.

Shutter opening too narrow - starving meter
of seed (low seed pool)

Adjust shutter to higher setting.

Y-tube partially or completely closed,
reducing bulk flow to meter or causing
bridging

Open Y-tube for row

Meter starvation due to bridging at shutter

Re-adjust for shutter bridging (page 76).
If seed is treated, increase seed lubricant.

Meter starvation due to bridging above inlet,
caused by low seed delivery air flow

Clear bridge (page 76). Check that seed delivery
system is getting sufficient fan air, and that there are
no other obstructions upstream.

Meter starvation due to bridging above inlet,
caused by high levels of seed treatment

Clear bridge (page 76). Increase seed lubricant.

Population Too Low

Problem

Cause

Solution