Console functions, Calibration, Console functions calibration – Great Plains 2510HDP Operator Manual User Manual
Page 74
70
1510HDP/2010HDP/2510HDP
Great Plains Manufacturing, Inc.
118-245M
2013-10-21
Console Functions
Refer to Figure 70
The use of each key is as follows:
• On/VR key-turns drive system on. Press twice for VR
mode. Note: Engage key must also be pressed to start
drive operation.
• Off key: used to shut off Console.
• Function key: used in calibration mode and to program
Console for VR recipes.
• Up/down arrow keys: used to change rates manually,
to set calibration numbers, and VR controller options.
• Engage key: press to start drive.
Note: Drive will not run unless light above key is illuminat-
ed.
Note: Figure 70 shows Main Operating Screen in manual
mode.
Calibration
Refer to Figure 71
1.
Turn on Controller Console by pressing On/VR key.
Green light above On/VR key will illuminate when
power is on. Adjust desired planting rate by using the
Up/Down arrow keys to change the Set rate.
2.
Set the desired Rate by using the Up/Down arrow
keys.
Refer to Figure 72
3.
Press Function key until Calibration Number window
appears.
4.
Select drive calibration number based on row
spacing and metering wheel, from chart. See
“Hydraulic Drive Calibration” on page 80.
5.
Use Up/Down arrow keys to set Calibration number.
Figure 70
Controller Key Functions
22710
Figure 71
Initiate Calibration
22715
Figure 72
Calibration Number Prompt
22716