beautypg.com

Singulator plus™ meter wheel replacement – Great Plains 3PYP Operator Manual User Manual

Page 76

background image

72

3PYP

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-312M

Table of Contents

Index

2014-09-09

Singulator Plus™ Meter Wheel
Replacement

Choose the correct seed meter wheel for the type of
seed you will be using. Be sure to use the same wheel
type on all meters.

25 Series Meter Wheels Not Interchangeable:
Seed meter wheels for the 25 Series row units are made of a
green color material and are not interchangeable with the
other Great Plains seed meter wheels, discs and plates for
other machines. Use only green wheels in 25 Series row units.

1.

Clean out meter. For more information, see “Meter
Removal
” on page 70

Refer to Figure 87

2.

Push in spring-loaded wheel retainer and make

1

4

turn. Pull off wheel retainer and spring.

Refer to Figure 88

3.

Pry the seed meter wheel out about

1

4

inch using

the tool stored under the walkboard, and spin
backward to clean out seeds from top pockets.

Refer to Figure 89

4.

Remove seed meter wheel.

Refer to Figure 90

Note: With the seed meter wheel removed, you may want

to check the meter for internal damage or trash.

Note: Some wear on top edge of slide is normal. Excess

wear is cause for replacement.

5.

When changing crops be sure to clean out air
system before installing new meters or wheels. See
Cleaning Out Air System” on page 87

6.

Place new wheel on meter wheel shaft. Seat wheel
fully on cross-pin.

7.

Replace spring-loaded wheel retainer. Make

1

4

turn

to seat cross-pin in shallow groove of retainer.

Figure 87

Singulator Plus™ Wheel Retainer

22911

Figure 88

Pry Meter Wheel

22913

Figure 89

Remove Wheel

25274

Figure 90

Inspect Meter

22884