Transmig vaf4 – Tweco VAF4 Transmig User Manual
Page 40

TRANSMIG VAF4
INSTALLATION, OPERATION AND SETUP
3-22
Manual 0-5231
Connecting Gas Hose to Solenoid
1. Place the hose clamp over the solenoid outlet.
2. Push gas hose onto solenoid outlet.
3. Slide the hose clamp over gas hose and tighten it with suitable crimping tool.
Hose Clamp
Gas Hose
Connected Gas Hose
Art # A-11635
Solenoid Outlet
Solenoid
Figure 3-16 Connecting Gas Hose to Solenoid
Connecting Welding Cable to Tweco No. 4 Adaptor
1. Attach the welding cable lug to Tweco No. 4 Torch Adaptor, using the M10 Flat Washer, M10 Spring
Washer and M10 x 15 Hex Bolt. Note that M10 x 15 Hex Bolt will need to be adjusted when installing
Tweco No. 4 Torch Adaptor.
Hex Bolt, M10 × 15
Welding Cable
Art # A-11365_AB
Spring Washer, M10
Flat Washer, M10
Torch Adaptor,
Tweco No. 4
Art # A-11366_AB
Welding Cable
Torch Adaptor,
Tweco No. 4
Figure 3-17 Connecting Welding Cable to Tweco No. 4 Torch Adaptor
Connecting Gas Hose to Tweco No. 4 Adaptor
1. Place the hose clamp over gas hose.
2. Push the gas hose onto the Tweco No. 4 Torch Adaptor gas inlet.
3. Slide the hose clamp forward until it sits approximately 5mm from the end of the gas hose.
4. Tighten the hose clamp with a suitable crimping tool.
Gas Hose
Hose Clamp
Art # A-11367_AB
Welding Cable
Gas Inlet
Torch Adaptor,
Tweco No. 4
Art # A-11368_AB
Welding Cable
Gas Hose
Torch Adaptor,
Tweco No. 4
Figure 3-18 Connecting Gas Hose to Tweco No. 4 Adaptor