Hmc-410, J1 j2, J7 j8 – Tweco HMC-410 User Manual
Page 95: Display/input microprocessor, S2 s3 s4 p.c. board p.c. board, J9 j10

HMC-410
July 27, 2005
A-5
DIAGRAM, CONNECTION & SCHEMATIC
HMC-410
NONE
1 OF 4
FULL
ATC
DBB
11-3-99
870241S1
11-3-99
ATC
ATC
11-3-99
130
TECH. PUB.
870241
DIGITAL +5 VDC
2
DIGITAL +5 VDC
3
DISPLAY A SELECT
4
DISPLAY B SELECT
5
DISPLAY C SELECT
6
DISPLAY DATA
7
DISPLAY CLOCK
8
ENCODER 1-A
9
ENCODER 1-B
10
ENCODER 2-A
11
ENCODER 2-B
12
ENCODER 3-A
13
ENCODER 3-B
14
ENCODER 4-A
15
ENCODER 4-B
16
CYCLE START
17
CYCLE STOP
18
TEST
19
INCH
20
PURGE
21
NOT USED
22
NOT USED
23
DIGITAL COM.
24
DIGITAL COM.
25
26
DIGITAL COM.
DIGITAL +5 VDC
1
120 VAC HI (OUT)
J1
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J1
J2
RELAY #1 CONTACT
7
RELAY #2 CONTACT
1
RELAY #2 CONTACT
2
3
ERROR RELAY CONTACT
4
ERROR RELAY CONTACT
5
6
RELAY #1 CONTACT
8
PS CONTACTOR LO
ARC VOLTS (+)
ARC AMPS (+)
REMOTE CONTROL MAX.
REMOTE CONTROL INPUT
ARC ESTABLISHED
ARC AMPS (-)
ARC VOLTS (-)
NOT USED
NOT USED
REMOTE START
REMOTE STOP
GUN SWITCH INPUT
AUX. PURGE
AUX. INCH
AUX. SUBSEGMENT ADV.
AUX. START/STOP
+15 VDC
+15 VDC UNREG.
TACH. SIGNAL
TACH. COM.
GAS VALVE INPUT
24 VAC HI
24 VAC LO
NOT USED
PS CONTACTOR HI
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J6
3
2
1
SUBSEGMENT ENABLE
J4
TRIGGER HOLD ENABLE
DIGITAL COM.
DIGITAL COM.
J5
PROG.\WELD ENABLE
1
2
3
DIG +5VDC
2
DIG +5VDC
3
DIG +15VDC
4
DIG -15VDC
5
NOT USED
6
EXT. AD7
7
EXT. AD6
8
EXT. AD5
9
EXT. AD4
10
EXT. AD3
11
EXT. AD2
12
EXT. AD1
13
EXT. AD0
14
EXT. INT
15
IF0
16
IF1
17
**WR
18
**RD
19
*ALE
20
XTAL1
21
XTAL2
22
*PSEN
23
DIG COM
24
DIG COM
25
26
DIG COM
DIG +5VDC
1
J7
J8
1
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
J3
1
A15
NOT USED
26
25
NOT USED
24
ABORT EN.
23
ENGLISH
22
HOLD EN.
21
PROGRAM DELAY EN.
20
SEGMENT SELECT
19
ARC HR RESET
18
TRIM EN.
17
DIAGNOSTICS EN.
16
A0
15
A1
14
A2
13
A3
12
A4
11
A5
10
A6
9
A7
8
A8
7
A9
6
A10
5
A11
4
A12
3
A13
2
A14
S1
12 (K)
120 VAC HI (IN)
PROG./WELD ENABLE
DIGITAL COM.
SUBSEGMENT ENABLE
DIGITAL COM.
TRIGGER HOLD ENABLE
DIGITAL COM.
DISPLAY/INPUT
MICROPROCESSOR
OPTIONAL
S2
S3
S4
P.C. BOARD
P.C. BOARD
LEGEND
S1 ON/OFF SWITCH WITH 4 AMP CIRCUIT BREAKER
S2 TRIGGER HOLD ENABLE SWITCH (OPTIONAL)
S3 SUBSEGMENT ENABLE SWITCH (OPTIONAL)
S4 PROGRAM/WELD SELECT SWITCH
T1 CONTROL TRANSFORMER
11 LINE
OPTIONAL
J9
J10
SEE SHEET 3 FOR OPTIONAL KIT SCHEMATIC
TB-1 TERMINAL BLOCK (OPTIONAL)
J11 SERIAL PORT (OPTIONAL)
SEE SHEET 3 FOR OPTIONAL KIT SCHEMATIC
CHANGE RECORD
E.C. No.
DATE
PLOT DATE
CHECKED
APPROVED
RECORDS
ITEM TYPE
DESIGNED
DRAWN
DATE
SCALE
COMM. CLS.
DESCRIPTIVE DATA
TITLE
MATERIAL SPEC.
MATERIAL NO.
ACTIVITY
FINISH CODE PER
REPLACED BY
REPLACES
QUANTITY-U.M.
DWG. NO.
SIZE
D
FRACT.
INCH
±
SHEET
FILE NAME
DISTRIBUTION TABLE
OUTSIDE DISTR.
6
5
4
3
2
1
4
5
6
1
2
3
H
G
F
E
D
C
B
A
CONFIDENTIAL: This drawing, including all information
contained thereon, is the exclusive and confidential property of
Thermal Arc Corporation of Troy, Ohio 45373 . This drawing is
not to be copied, reproduced, delivered or disclosed to others,
in whole or in part, except with express written permission.
TROY, OHIO 45373 , U.S.A.
ANGLES
± 3˚
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES/MILLIMETERS
TOLERANCES BELOW APPLY EXCEPT FOR
VENDOR DESIGNED PARTS AND ITEMS.
PRODUCED TO RECOGNIZED STANDARDS.
DECIMAL-INCH
METRIC
0.00 ± 0.1mm
0.0 ± 0.4mm
0. ± 1.0mm
.000 ± .003
.00 ± .02
DO NOT SCALE DRAWING
.0 ± .1
A THERMADYNE Company
R
R
Art #A-05056