Ethernet communication specifications, Recommended pc ip address – Banner PresencePLUS Pro—PRO Camera User Manual
Page 34

01/04
Specifications
PresencePLUS
®
Pro
Banner Engineering Corp. • Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
28
P/N 68368 rev. B
01/04
-------------------------------------------------------------------------------
Ethernet Communication Specifications
Use a crossover Ethernet cable for communicating directly with a PC. Use a straight Ethernet cable for
communicating with a network device, such as an Ethernet hub or switch.
Protocol
TCP/IP
Data Transfer Rate
10/10 Mbps
Max. Cable Length
120 m (393')
Recommended PC IP Address
192.168.0.2
PC Subnet Mask
255.255.255.0
Factory Default PresencePLUS Pro
IP Address
192.168.0.1
Connector
RJ-45
Connector Pin-Out
---------------------------------------
Use an RJ45 network crossover cable for direct connection to a PC.
Pin 1: TXD+
Pin 2: TXD–
Pin 3: RXD+
Pin 4: Not used
Pin 5: Not used
Pin 6: RXD–
Pin 7: Not used
Pin 8: Not used
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
PC End of Cable