ClearCube PCoIP System User's Guide User Manual
Page 83
Chapter 6. Configuring Devices, Setting Peers, and Connecting
76
PCoIP System User’s Guide
The following figure shows the architecture described in this section.
Figure 35. Unmanaged SLP assignment with direct connection (no network connection)
NOTE: You must have a physical connection to a computer running a Web browser to view the
PCoIP browser-based management interface. A direct connection between a host card
and a zero client does not provide the Web interface. To use the Web interface to
configure a host, connect a computer running the Web interface to the host card. After
working with the Web interface, you can reconnect the zero client to the host.
NOTE: ClearCube recommends using static IPs in this configuration. Using static, fallback IP
addresses significantly increases the time for devices to become available because
fallback IP addresses are only available after a timeout period.
1. Connect the chassis and the zero client.
a. Connect one end of a CAT5 or CAT6 Ethernet cable to the appropriate port on your chassis.
R4300 chassis—insert the cable in the Secondary Network port.
A3100 chassis—insert the cable to the PCoIP port.
b. Connect the other end of the cable to the RJ-45 connector on the zero client.
2. Configure networked devices as described in
Port and Protocol Requirements
” on page
Mandatory Network-Related Settings
” on page
3. Configure the zero client.