ClearCube PCoIP System User's Guide User Manual
Page 36
3.6 Bandwidth Limiting
ClearCube Technology, Inc.
29
Field
Description
moving the slider towards Reduced allows higher frame rates.
Moving the slider towards Perception-Free allows for higher
image quality. When network bandwidth is not constrained,
the PCoIP system maintains perception-free quality
regardless of the Minimum Image Quality parameter.
NOTE: The Minimum Image Quality must be less than or
equal to the Maximum Initial Image Quality. It does not have a
corresponding parameter on the OSD as it is an administrator-
only parameter.
Maximum Initial Image
Quality
Use the slider to reduce the network bandwidth peaks caused
by screen content changes. This parameter limits the initial
quality on the first display frame of a screen change.
Unchanged regions of the image are built to a lossless state
regardless of this parameter.
NOTE: The Maximum Image Quality:
must be greater than or equal to the Minimum Image Quality
does not have a corresponding parameter on the OSD as it is
an administrator-only parameter
Image Quality Preference
Use the slider to set if you want the image to favor image
sharpness versus smooth motion during a PCoIP session
when network bandwidth is limited.
NOTE: This field is also accessible on the host if the PCoIP
Host Software is installed. The slider appears in the host
software’s Image tab. This setting does not work in PCoIP
sessions with VMware View virtual desktops running release 5.0
or earlier.
Maximum Frame Rate
The maximum frame rate helps you manage multiple PCoIP
sessions over a single network link. This setting determines
the limit that your users can reach. Set this field to 0 to set no
frame limit. If you set a value, a single user is limited to that
value. This helps to control the user experience for all your
users.
NOTE: The Maximum Frame Rate does not have a
corresponding parameter on the OSD as it is an administrator-