6.6 Connecting to a Device

ClearCube Technology, Inc.

73

a. Connect one end of a CAT5 or CAT6 Ethernet cable to the appropriate port on

your chassis.

R4300 chassis—insert the cable in the Secondary Network port.

A3100 chassis—insert the cable in the PCoIP port.

b. Connect the other end of the cable to a network switch on a known subnet.

3. Connect the zero client to a network switch.

a. Connect one end of a CAT5 or CAT6 Ethernet cable to the RJ-45 connector on the zero client.

b. Connect the other end of the cable to a network to a switch connected to the chassis. This

switch can be the same switch used in the previous step.

Ensure network device ports are configured as described in

3.8

Port and Protocol

Requirements

on page

31

, and devices meet all network-related requirements as described in

4.4

Mandatory Network-Related Settings

on page 39

.

4. Configure the zero client.

a. Briefly press the power button on the front of the zero client to power it on. The zero

client displays a dialog box.

b. In the upper–left corner of the screen, click Options > Configuration to open the

Configuration page. Click Unlock on the lower–left portion of the page to display the
Unlock dialog box. Click OK to unlock the page (you should not need to type a
password).

c. In the Network tab, ensure that the Enable DHCP option is cleared. Specify the

following for the zero client:

 IP addresses

 Subnet mask

 Gateway

These values can be any value appropriate for your environment.

d. Click Apply and then click Reset in the Attention dialog box to reset the zero client.

e. In the upper–left corner of the page, click Options > Configuration to open the

Configuration page. Click Unlock on the lower–left portion of the page to display the
Unlock dialog box. Click OK to unlock the page (you should not need to type a password).