Rockwell Automation 2097-V3xPRx-LM Kinetix 300 and Kinetix 350 Drive Systems Design Guide User Manual
Page 57

Rockwell Automation Publication GMC-RM004C-EN-P - September 2013
57
Kinetix 300 and Kinetix 350 Drive Systems
Performance Specifications with Kinetix 300/350 (400V-class) Drives
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Kinetix 300/350 Drives/MP-Series Electric Cylinder Curves
Electric Cylinder
Speed, max
mm/s (in/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Motor Rated
Output
kW
Kinetix 300/350
400V-class
Three-phase Drives
MPAR-B1
xxxB
150
1.15
240 (53.9)
1.35
300 (67.4)
0.036
2097-V34PR3-
xx
MPAR-B1
xxxE
500
1.49
280 (62.9)
1.71
350 (78.7)
0.140
MPAR-B2
xxxC
250
1.67
420 (94.4)
1.90
525 (118)
0.105
MPAR-B2
xxxF
640
3.29
640 (144)
3.93
800 (180)
0.410
2097-V34PR5-
xx
MPAR-B3
xxxE
500
5.16
2000 (450)
6.17
2500 (562)
1.00
MPAR-B3
xxxH
1000
6.13
1300 (292)
6.79
1625 (365)
1.30
2097-V34PR6-
xx
500
400
300
200
100
0
112
89.9
67.4
45.0
22.5
0
Velocity (mm/s)
150
100
0
200
50
2097-V31PR0, 2097-V32PR0, or 2097-V33PR1
and MPAR-A1
xxxB-VxA
2097-V34PR3 and MPAR-B1
xxxB-VxA
Force
(N)
Force
(lb)
500
400
300
200
100
0
112
89.9
67.4
45.0
22.5
0
Force
(N)
Force
(lb)
Velocity (mm/s)
100
400
300
0
600
500
200
2097-V31PR0, 2097-V32PR0, or 2097-V33PR1
and MPAR-A1
xxxE-VxA
2097-V34PR3 and MPAR-B1
xxxE-VxA
Force
(N)
Force
(lb)
Velocity (mm/s)
50
200
150
0
300
250
100
22.5
45.0
67.4
89.9
112
135
0
100
200
300
400
500
600
700
157
0
2097-V31PR0, 2097-V32PR0, or 2097-V33PR1
and MPAR-A2
xxxC-VxA
2097-V34PR3 and MPAR-B2
xxxC-VxA
1000
800
600
400
200
0
Velocity (mm/s)
600
400
0
800
200
Force
(N)
Force
(lb)
225
180
135
89.9
45.0
0
500
300
700
100
2097-V31PR2, 2097-V32PR2, or 2097-V33PR3
and MPAR-A2
xxxF-VxA
2097-V34PR5 and MPAR-B2
xxxF-VxA
= Intermittent operating region
= Continuous operating region