Rockwell Automation 2097-V3xPRx-LM Kinetix 300 and Kinetix 350 Drive Systems Design Guide User Manual
Page 42

42
Rockwell Automation Publication GMC-RM004C-EN-P - September 2013
Kinetix 300 and Kinetix 350 Drive Systems
Kinetix 300 (200V-class) Drives/LDAT-Series Integrated Linear Thruster Curves (continued)
LDAT-Series Performance Specifications with Kinetix 300 (400V-class) Drives
Performance Specifications with Frame 30 Linear Thrusters
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 300
(400V-class) Drives
Three-phase Operation
LDAT-S031010-D
xx
2.4
4.8
81 (18)
12.2
168 (38)
0.20
2097-V34PR5
LDAT-S031020-D
xx
3.1
0.25
LDAT-S031030-D
xx
3.5
0.29
LDAT-S031040-D
xx
3.8
0.31
LDAT-S032010-D
xx
3.1
7.4
126 (28)
24.3
336 (76)
0.40
2097-V34PR6
LDAT-S032020-D
xx
4.1
0.52
LDAT-S032030-D
xx
4.7
0.59
LDAT-S032040-D
xx
5.0
0.63
LDAT-S032010-E
xx
3.1
3.7
12.2
0.40
2097-V34PR5
LDAT-S032020-E
xx
4.1
0.52
LDAT-S032030-E
xx
4.7
0.59
LDAT-S032040-E
xx
5.0
0.63
LDAT-S033010-E
xx
3.5
3.7
190 (43)
12.2
504 (113)
0.67
2097-V34PR5
LDAT-S033020-E
xx
4.7
0.87
LDAT-S033030-E
xx
5.0
0.91
LDAT-S033040-E
xx
180
360
540
719
899
1079
0
800
1600
2400
3200
4000
4800
5600
1259
0
Force
(N)
Force
(lb)
2097-V33PR5 and LDAT-S156090
-Exx
Velocity (m/s)
0
1.50
1.0
1.75
0.25
180
360
540
719
899
1079
0
800
1600
2400
3200
4000
4800
5600
1259
0
Force
(N)
Force
(lb)
2097-V33PR6 and LDAT-S156090
-Dxx
Velocity (m/s)
0
1.0
2.0
1.5
0.5
= Intermittent operating region
= Continuous operating region
= Intermittent operating region with 115V AC rms input voltage