Offline Operating Modes
4–12
Publication 2706-6.1
Where the Strobe Lines Mnemonic is an abbreviation for the state of
the four strobe lines MS0, MS1, MS2, MS3. The interpretation of
these lines is dependent on the Run Mode selected by the user with
the Offline Programming Software.
The Data Lines State will be a pattern of sixteen 1s and 0s indicating
the voltage state of the data inputs D0–D15.
Voltage Range
High True Logic
Low True Logic
0 – 0.8 VDC
0 (OFF)
1 (ON)
0.8 – 3.5 VDC
Indeterminate
Indeterminate
3.5 – 25 VDC
1 (ON)
0 (OFF)
You select the type of logic to use when programming the DL40 Plus
with the Offline Programming Software.
The Strobe Lines Mnemonic will occupy the first three positions of
the display (starting from the left). This will be followed by a space
character and then the state of D15, D14, D13 and so on until the
state of D0 which will be in the far right position of the display. The
following table shows the mnemonics that will be displayed for the
strobe lines for different Run Modes.
High True or Low True Logic
Run Mode
MS3
MS2
MSl
MS0
Mnemonic
Msg/Var/Slave
0
0
0
0
NUL
0
0
0
1
MSG (Message)
0
0
1
0
SLV (Slave)
0
0
1
1
SGN (Sign)
1
0
0
0
D1 (Variable 1)
1
0
0
1
D2 (Variable 2)
1
0
1
0
D3 (Variable 3)
1
0
1
1
D4 (Variable 4)
1
1
0
0
D5 (Variable 5)
1
1
0
1
D6 (Variable 6)
1
1
1
0
D7 (Variable 7)
1
1
1
1
D8 (Variable 8)
0
1
1
0
D9 (Variable 9)
0
1
1
1
D10(Variable 10)
0
1
0
0
NV(Not Valid)
0
1
0
1
INV(Invalid)
Message List
➀
X
X
0
0
NUL
X
X
0
1
PRl (Priority)
X
X
1
0
ADD
X
X
1
1
DEL (Delete)
➀
X = Ignored