Clock mode – Rockwell Automation 2706-LV2P_LV2R_LV4P_LV4R DL40 PLUS USER MANUAL User Manual
Page 62

Offline Operating Modes
4–9
Publication 2706-6.1
This mode lets you set the battery-backed real-time clock by entering
a
[CTRL]
[
C
]
via the DL40 Plus Keyboard Port or by the using the
[SELECT]
and
[
↵
]
front panel push buttons. This mode can only be
entered if the DL40 Plus is in Run Mode.
Using a Keyboard
When you enter Clock mode from a keyboard, you will receive the
following prompts (one at a time):
SET CLOCK
SHOW CLOCK
RETURN TO RUN MODE
Enter
[Y]
or
[N
]
followed by
[
↵
]
for each prompt. If you enter
[N]
to
return to Run Mode, the DL40 Plus goes back to the first prompt.
Pressing
[ESC]
or
[MSG ACK
]
immediately returns you from the
Clock mode prompts to the Run mode. Pressing
[ESC]
or
[MSG ACK]
while Setting or Showing the clock immediately returns you to the
Clock mode prompts. If the DL40 Plus is performing a clock
function, that function will be aborted.
Using the Front Panel Push Buttons
Use the
[SELECT]
push button to increment or toggle through
settings. Press
[
↵
]
when the correct data is displayed.
After SECONDS are entered, the new clock data will be saved and
the DL40 Plus will display the SET CLOCK prompt.
If Set Clock is aborted by using a
[MSG ACK]
, real time clock data
will remain unchanged.
Note: The clock can also be set (while the DL40 Plus remains in
Run Mode) by triggering Special Message 910 or 911.
Clock Mode