9 - installation and wiring, Chapter objectives, Mounting the dl40 plus – Rockwell Automation 2706-LV2P_LV2R_LV4P_LV4R DL40 PLUS USER MANUAL User Manual
Page 130: Installation and wiring, Chapter, Chapter objectives mounting the dl40 plus
Chapter
9
Installation and Wiring
This chapter describes how to mount and wire the DL40 Plus to your
control system.
Section
Page
Mounting the DL40 Plus
9–1
Panel Cutout Dimensions of the 2-Line DL40 Plus
9–2
Panel Cutout Dimensions of the 4-Line DL40 Plus
9–3
Dimensions of the 2-Line DL40 Plus
9–4
Dimensions of the 4-Line DL40 Plus
9–5
Electrical Precautions
9–6
Input Voltage Requirements
9–6
Hazardous Location Installation
9–6
Wiring the DL40 Plus
9–7
Remote I/O Connector
9–8
Connecting to a Scanner Module
9–9
Parallel Port
9–10
Connecting the RS-485 Port for Open Protocol
9–11
Connecting a Programmer to the RS-485 Port
9–12
Connecting DL Slaves to the RS-485 Port
9–13
RS–232 Port
9–14
Alarm Relay
9–14
Keyboard Port
9–14
AC Power Connector
9–15
The figures in the following sections provide panel cutout
dimensions and overall dimensions for the DL40 Plus.
You can mount the DL40 Plus in a custom panel or enclosure. When
the DL40 Plus is properly installed, the faceplate of the DL40 Plus
provides a NEMA Type 12, 13, and 4X (indoor) enclosure integrity.
To install the DL40 Plus, perform the following steps:
1. Cut and drill the appropriate mounting holes in the enclosure or
panel.
2. Remove the six mounting nuts from the mounting stud bag
included with the DL40 Plus.
3. Position the DL40 Plus in the panel or enclosure mounting hole.
4. Install and tighten the six mounting nuts to a torque of 10 in
•
lbs
(1.13N
•
m) each.
Chapter Objectives
Mounting the DL40 Plus