Specifications

Character Height

Two line display
Four line display

11.3 mm (0.44 inch)
11.3 mm (0.44 inch)

Character Set

Table 1 English
Table 2 Cyrillic
Table 3 International

Standard & Extended ASCII Characters
Standard and Cyrillic (Russian) Characters
International ISO 8859–1 Characters

Characters Per Diaplay Line

20

Viewing Distance – Approximate

7.6 meters (25 feet)

Character Type

Vacuum fluorescent, 5x7 dot matrix characters
Filtered to blue/green color

Display Luminance

Adjustable 0 to 100% brightness level

Input Voltage

100 – 240 VAC , 50–60 Hz , 0.60 - 0.25A

Input Power

60 VA

Fuse Type

Internal sealed (not user replaceable)

Annunciation Relay

AC Resistive Load
DC Resistive Load

One N.O. Contact
3 Amperes at 240 V AC
3 Amperes at 30 V DC

Electrical Interface

Direct Connection – Single Point
Network Connection – Multi–Drop

RS–232 (EIA–/TIA–232–E)
RS–485 (EIA–485)

Baud Rate

300, 1200, 2400, 4800, 9600,19200

Data Format

7 or 8–data bits – odd, even, or no parity

Electrical Interface

Allen–Bradley Remote I/O Link

Remote I/O Baud Rate

57.6K, 115.2K, or 230.4K

Maximum I/O Cable Distance

10,000 feet (2800m) for 57.6K baud
5000 feet (1400m) for 115.2K baud
2500 feet (700m) for 230.4K baud

Rack Sizes

1

/

4

,

1

/

2

,

3

/

4

or 1 (any starting module)

Data Transfer Type

Discrete I/O or Block Transfers

Electrical Interface

Parallel Input Port

Logic Low
Indeterminate
Logic High

0 to 24 VDC
High True Logic Low True Logic
0 - 0.8 VDC 3.5 - 24 VDC
0.8 - 3.5 VDC 0.8 - 3.5 VDC
3.5 - 24 VDC 0 - 0.8 VDC

Data Lines

16 Data Lines, plus 4 Strobe Lines

Input Current

5mA per data line at 12 Volts DC

Output Supply

+ 12 Volts DC output voltage source provided,
200mA maximum

Display Characters

Electrical

Serial
Communications Ports

PLC Remote I/O
Communications Port
(RIO versions only)

Parallel Communications Port