System requirements, Hardware requirements, Software requirements – Rockwell Automation 6723-PCO DATA PROCESS CONFIG OPERATIO User Manual
Page 4

Process Configuration and Operation Software for Windows
t
2
Publication 6723Ć10.1 Ć August 1996
Hardware Requirements
PCO supports any combination of hardware from this list.
Requirement:
Options:
Computer
IBM PC Compatible 386/486/586 (Pentium), with at least 8 mb RAM and 14 mb Hard Drive space available.
Note: If you are running the PCO software tools and an MMI on this system, we highly recommend that you use at least 16
mb RAM.
PLC Processors
PLCĆ5/30
series A and later
PLCĆ5/40
series B and later
PLCĆ5/60
series B and later
PLCĆ5/80
series C and later
I/O Module(s)
1771ĆNBRC HighĆresolution Isolated Analog
(RTD Input; 4Ć20mA Output)
1771ĆCFM Configurable Flowmeter
1771ĆNBTC HighĆresolution Isolated Analog
(TC/mV Input; 4Ć20mA Output)
1771ĆIFE Analog Input
1771ĆNBVC HighĆresolution Isolated Analog
(+5V Input; 4Ć20mA Output)
1771ĆIL Isolated Analog Input
1771ĆNIS HighĆresolution Isolated Analog (4Ć20mA Input)
1771ĆIR RTD Input
1771ĆNIV HighĆresolution Isolated Analog (+5V Input)
1771ĆIXE Thermocouple
1771ĆNIVR HighĆresolution Isolated Analog (+5V Input)
1771ĆIXHR HighĆresolution Thermocouple
1771ĆNIVT HighĆresolution Isolated Analog
(+5V Input; TC/mV Input)
1771ĆQRD Pulse
1771ĆNOC HighĆresolution Isolated Analog (4Ć20mA Output) 1771ĆOFE Analog Output
1771ĆNOV HighĆresolution Isolated Analog (+10V Output)
1771ĆNR HighĆresolution Isolated Analog (RTD Input)
1771ĆNT1 HighĆresolution Isolated Analog (TC/mV Input)
PanelView Terminal
(optional)
2711 Series (keypad version only)
Note: PLC-5/11 and -5/20 processors may also be used under some
circumstances. While use of these processors for PCO is somewhat
limited by memory considerations, their use may still be feasible,
depending on your applications and the number of PCO functions
you need. Use the sizing spreadsheet to determine if you will be able
to run your applications with these processors.
Note: There are many other build-to-order N-Series modules that
may be compatible with this software that are not listed here. Check
with your Allen-Bradley representative to determine compatibility.
Software Requirements
You need this software to run PCO.
Requirement:
Options:
operating system
Windowst 3.x or Windowst 95
operator interface
FactoryĆLinkt, FIXt, or RSViewt MMI system
1
application software
Microsoft Excelt 5.0 or Microsoft Excelt for Windows 95
pp
INTERCHANGEt 6.1.0 or later (cat. no. 9351ĆWKTSR)
PanelBuildert Software (cat. nos. 2711ĆKA1, ĆKC1, ĆND1, ĆTA1,
and ĆTC1) if you plan to use PanelView screens
PLCĆ5 Programming Software
1
(6200 Series, AI, or WinLogic))
1
Contact your local AllenĆBradley representative for a list of other compatible operator interface and PLC
processor programming software packages.
System Requirements