Chapter
Programming Block-Transfers

5

5 -10

Asynchronous Block Transfer

You can use this ladder logic program with PLC-5 processors for
asynchronous block transfer. This program assumes that your application
requires a single block- transfer-read (BTR) and block-transfer-write
(BTW) to pass data between the processor and the BASIC module (transfer
of 64 words or less). If transferred data exceeds 64 words you must
program multiple file-to-file moves to move different data sets to and from
block-transfer files.

Rungs 1 and 2 execute the BTR and BTW instructions alternately.
When BTR is completed, BTW enables immediately following BTR scan.

Important: Do not select the continuous mode when using bi-directional
block-transfer. Continuous mode does not allow use of the status bits in
the block-transfer instructions.

BTW

BLOCK XFER WRITE

Rack

Group

Module

0

0

0

N10:10

N10:15

5

Control Block

Data file

Length

File 2,

15

Rung 0

15

Continuous

N

N10:10 N11:10

BTR

BLOCK XFER READ

Rack

Group

Module

0

0

0

N11:10

N11:15

5

Control Block

Data file

Length

File 2,

15

Rung 1

15

Continuous

N

N10:10 N11:10

File 2, Rung 2

[END OF FILE]