13 - call routines 69–127, Chapter, What’s in this chapter – Rockwell Automation 1771-DB BASIC MODULE User Manual
Page 259

13
Chapter
13 -1
Call Routines 69–127
There are 128 BASIC calls. Calls 69 – 127 are described here.
Calls 0 – 68 are described in Chapter 12. Chapter 7 gives you an overview
of how to use these calls within your BASIC program. Use these calls
within your BASIC program or from the command line.
Important: CALL numbers above 127 are not valid and cause the BASIC
module error–
ERROR CALL ARGUMENT OUT OF RANGE.
CALL
Description
Page
CALL
Description
Page
69
undefined
99
reset print head pointer
70
ROM to RAM program transfer
100
download/program assembly language to EEPROM
71
ROM/RAM to ROM program transfer
101
upload user (E)EPROM code to host
72
RAM/ROM return
102
undefined
73
battery-backed RAM disable
103
print PRT1 transmit buffer and pointer
74
battery-backed RAM enable
104
print PRT1 receive buffer and pointer
75
undefined
105
reset PRT1 to default settings
76
undefined
106
undefined
77
protected variable storage
107
undefined
78
set program port communication rate
108
enable DF1 driver communications
79
set active LED blinking state (no operation)
109
print the argument stack
80
check battery condition
110
print the PRT2 port transmit buffer and pointer
81
user PROM check and description
111
print the PRT2 receive buffer and pointer
82
check user memory module map
112
user LED control
83
display DH485 port setup
113
disable DF1 driver communications
84
transfer DH-485 CIF to BASIC input buffer
114
transmit DF1 packet
85
transfer BASIC output buffer to DH-485 CIF file
115
check DF1 status
86
check DH-485 interface remote write status
116
call user defined assembly language routine
87
check DH-485 interface file remote read status
117
get DF1 packet length
88
BASIC floating point to PLC-5 floating point
118
PLC/SLC unsolicited writes
89
PLC-5 floating point to BASIC floating point
119
reset PRT2 port to default settings
90
read remote DH-485 data file to BASIC input buffer
120
clear BASIC module I/O buffers
91
write BASIC output buffer to remote DH-485 data file 13 -22
121
undefined
92
read remote DH-485 CIF to BASIC input buffer
122
read remote DF1 PLC data file
93
write output buffer to remote DH-485 CIF file
123
write to remote DF1 PLC data file
94
display current PRT1 port setup
124
undefined
95
get number of characters in PRT1 buffers
125
undefined
96
clear PRT1 receive/transmit buffers
126
undefined
97
enable PRT2 DTR signal
127
undefined
98
disable PRT2 DTR signal