Chapter
Call Routines 69–127

13

13 -2

Undefined. If you execute an undefined call, you receive the error
message, “

ERROR–UNSUPPORTED CALL

.”

Use this routine to shift program execution from a running ROM program
to the beginning of the RAM program.

Important: The first line of the RAM program is not executed.
We recommend that you make it a remark.

Important: There must be a next line in the ROM or RAM routine,
otherwise unpredictable events could occur that may destroy the contents
of RAM. For this reason always be sure that at least one END statement
exists following a CALL 70 or 71.

Input and Output Arguments

This routine has no input or output arguments.

Syntax

CALL 70

Example

>ROM5

>LIST

10 REM SAMPLE ROM PROG FOR CALL 70

20 PRINT “NOW EXECUTING ROM #5”

30 CALL 70 : REM GO EXECUTE RAM

40 END

>RAM

>LIST

10 REM SAMPLE RAM PROGRAM FOR CALL 70

20 PRINT “NOW EXECUTING RAM”

30 END

>ROM5

>RUN

NOW EXECUTING ROM #5

NOW EXECUTING RAM

CALL 69

CALL 70: ROM to RAM
Program Transfer