Add i/o modules to your network – Rockwell Automation 1734-VHSC24 Very High-Speed Counter Modules User Manual User Manual
Page 44
Publication 1734-UM003B-EN-P - August 2005
4-2 Configure Your Module
Add I/O Modules to Your Network
After you add the communication device, you must add the POINT
I/O modules connected to the scanner on the POINTBus. Use these
procedures.
1. From the DeviceNet - RSNetWorx for DeviceNet dialog, click +
next to Specialty I/O module to expand the selection.
2. From the DeviceNet - RSNetWorx for DeviceNet dialog, to
choose a module, do one of the following, as shown in the
figure.
• Double-click the catalog number to choose the module.
• Click and drag the module name onto the network.
1. Click here to expand the list
of communication adapters.
2. Double-click here to choose
the scanner. You can also
click and drag the scanner
name onto the network.
Make sure you choose the
1734-ADN POINT I/O
Scanner.
The scanner appears
on the network.