beautypg.com

Rockwell Automation 1336T Function Block Prog. Manual, Series A/B User Manual

Page 23

background image

1–11

Getting Started

1336 FORCE — 5.9 August 1995

Step 6 — Check Links

Once all function blocks and their links have been established, node
connections in the program should be validated by using a

Check

Node Connections

command from the

Function Blocks

pull-down menu. This function is performed by the
DriveBlockEditor, not the drive.

If all links are correct, the following display will be shown.

If any errors were made, a Connection Errors Dialog Box will detail
the errors.

Step 7 — Download the Program

Once the links have been checked, the execution list must be
downloaded to the drive to enable the function block program.

1. Select the

Download to Drive

option from the

DriveBlockEditor’s pull-down

Drive

menu. If you know the

station number, enter it at this time. If the Station number is
unknown, use the

WHO

menu option shown below to scan for

active DH+ stations.

2. During the download process, the drive checks function block

links and node values. A message will appear telling you whether
the download was successful.