beautypg.com

Limit, Set reset ff, Multiplexer – Rockwell Automation 1336T Function Block Prog. Manual, Series A/B User Manual

Page 22: Rate limiter

background image

1–10

Getting Started

1336 FORCE — 5.9 August 1995

Press the enter key to save the value as shown below.

Step 5 — Modify the Limit Block

1. Move to the Limit function block node entry field by clicking on

ID # 1

. Link the Limit’s input (node 0), to the Rate Limiter’s

output (node 5).

Click on the

Link To

field for

Node 0

and enter

4:5

.

Press the enter key to save the value as shown below.

The block diagram is now complete and should appear as shown
below with the Rate Limiter function block added.

Input 1 1:0

Max Val (32767) 1:1

LIMIT

ID # 1

@ Max Lim !:3

@ Min Lim 1:4

Output 1:5

Min Val (–32767) 1:2

Set Reset FF

ID # 2

Set 2:0

Reset 2:1

Out1 2:2

Out2 2:3

Output 3:6

In1 (32767) 3:0

In2 (–32767) 3:1

In3 3:2

In4 3:3

Sel0 3:4

Sel1 3:5

Multiplexer

ID # 3

Lim @Lim 4:4

Lim In 4:0

Lim Set 4:1

Lim Data 4:2

Lim Rate 4:3 (65535)

Lim Out 4:5

Rate Limiter

ID # 4