beautypg.com

Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual

Page 67

background image

Start-Up

4-9

Apply Power to Drive

❏ 17. Check for Correct Motor Rotation.

Slowly Increase Speed

Verify Direction

of Rotation

or

Verify Frequency

Command = 0

a.) Reapply power to the drive.

b.) Verify that the frequency command is at zero Hz. Refer to step 11 for

further information.

c.) Start the drive.

d.) Slowly increase the speed until the motor begins to turn. Check the

direction of motor rotation.

e.) Stop the drive. If the direction of rotation is as desired, proceed to step

18.

If the direction of rotation is incorrect - disconnect and lock-out all input
and control power to the drive. When the HIM Display is no longer
illuminated, remove the drive cover. Verify that the DC Bus neon
indicator is not illuminated (see Figure 2.3 for location) and wait 60
seconds. Interchange any two of the three motor leads at TB1 terminals,
T1, T2 or T3. Replace the drive cover and repeat steps a – e to verify
correct motor rotation.

At Speed
+5.00 Hz

Stopped
0.00 Hz

At Speed
+5.00 Hz

Stopped

+0.00 Hz