Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual
Page 142
Block Diagram and Specifications
A-6
Table A.1 Specifications
(continued)
PROGRAMMING/COMMUNICATIONS
Adapters
The maximum current draw of all adapters connected to the drive should not exceed 250 mA
Hand Held Programming
Optional Human Interface Module (HIM can be removed from the Drive)
Type of Annunciation
Parameters displayed in textual form, organized in Iogical groupings
Type of Display
16 character, 2 line LCD supertwist with backlight
Language Capability
Multiple Languages available
Local Controls
3 versions available ( Digital Pot., Analog Pot. and Blank)
Communication Adapters
Optional adapters provide Remote I/0, or RS232/RS422/RS485/DF1/DH485, or DeviceNet
capability
MONITORING
Output Frequency (Hz)
Displayed over the entire range of operation with direction indication
Output Voltage (V)
Selectable as a displayed parameter
Output Current (A)
Selectable as a displayed parameter in % or actual value
Output Power (kW)
Selectable as a displayed parameter in % or actual value
DC Bus Voltage (V)
Selectable as a displayed parameter
Frequency Command (Hz)
Selectable as a displayed parameter
Process Parameter
Any drive variable can be scaled and definable text can be added up to 8 characters
Drive Temperature
_C
Selectable
as a
displayed parameter
Last Fault
The previous 4 faults can be displayed for troubleshooting