Safety Monitoring Functions

Chapter 9

The available input selections for the Enabling Switch inputs are:

EI_00…EI_11 (embedded input terminals 00…11)

MP_12…MP_17 (multi-purpose terminals 12…17)

You can modify the number and types of inputs:

2 N.C.

2 OSSD

1 N.C.

Pulse testing can be disabled or set to 2 Sources. When 2 Sources is selected, the
next available test sources are automatically selected. You can modify the sources
afterward.

You can use the default Discrepancy Time and Input Filter or choose to modify
these settings.

Figure 34 - Example Schematic of a Dual Channel Enabling Switch Without Test Pulses

Figure 35 - Example Schematic of a Dual Channel Enabling Switch Using Test Pulses A and B