Verification – Rockwell Automation 440C Guardmaster 440C-CR30 Configurable Safety Relay User Manual User Manual
Page 30
30
Rockwell Automation Publication 440C-UM001C-EN-P - November 2014
Chapter 4
Configuring the CR30
Verification
After validation, you can assign a unique verification ID to the current
configuration in Connected Components workbench. Any change to a verified
configuration invalidates the verification ID and requires a new validation and
verification process.
To complete the validation and verification, you finally have to acknowledge that
the safety configuration and installation meets the operational and
environmental specification of the machine. Relevant documentation:
•
Details of the authorized and responsible personnel
•
Revision of the firmware of the CR30
•
Version of the Connected Components workbench
•
Identification of the configured safety function and project
16.
The CCW must be connected to the CR30 during verification.
17.
The CR30 must be in Program mode.
18.
Click the Verify button (the Safety Verification window appears).
19.
Answer all questions and check each box, if completed.
20.
Click Generate.
IMPORTANT
The verification process must be documented in the safety system
technical file.
Use the
Configuration Reference Document on page 139
or the verification
report feature in CCW release 7 or higher.
ATTENTION: The verification process should be documented in the safety
system technical file.