Instance attributes – Rockwell Automation 20-COMM-R Remote I/O Adapter User Manual
Page 92

C-6
CIP Objects
20-COMM-R Remote I/O Adapter User Manual
Publication 20COMM-UM004D-EN-P
Instance Attributes
Attribute ID Access Rule
Name
Data Type
Description
7
Read Only
DPI Online Read Full
STRUCT of:
BOOL[32]
CONTAINER
(1)
CONTAINER
CONTAINER
CONTAINER
WORD
WORD
STRING[4]
UINT
UINT
UINT
INT
BYTE[3]
BYTE
STRING[16]
Descriptor (see
Parameter value
Minimum value
Maximum value
Default value
Next parameter
Previous parameter
Units (for example, Amp, Hz)
Multiplier
(2)
Divisor
Base
Link (source of the value) (0 = no link)
Always zero (0)
Parameter name
8
Read Only
DPI Descriptor
BOOL[32]
Descriptor (see
9
Read/Write
DPI Parameter Value
Various
Parameter value in NVS.
(3)
10
Read/Write
DPI RAM Parameter Value
Various
Parameter value in temporary memory.
11
Read/Write
DPI Link
BYTE[3]
Link (parameter or function block that is the
source of the value) (0 = no link)
12
Read Only
Help Object Instance
WORD
ID for help text for this parameter
13
Read Only
DPI Read Basic
STRUCT of:
BOOL[32]
CONTAINER
CONTAINER
CONTAINER
CONTAINER
STRING[16]
STRING[4]
Descriptor (see
Parameter value
Minimum value
Maximum value
Default value
Parameter name
Units (for example, Amp, Hz)
14
Read Only
DPI Parameter Name
STRING[16]
Parameter name
15
Read/Write
DPI Parameter Alias
STRING[16]
Customer supplied parameter name.
16
Read Only
Parameter Processing Error BYTE
0 = No error
1 = Value is less than the minimum
2 = Value is greater than the maximum
(1)
A CONTAINER is a 32-bit block of data that contains the data type used by a parameter value. If signed, the value is sign extended. Padding is
used in the CONTAINER to ensure that it is always 32-bits.
(2)
This value is used in the formulas used to convert the parameter value between display units and internal units. See
(3)
Do
not continually write parameter data to NVS. See the attention on
.