beautypg.com

Install components – Rockwell Automation 20B PowerFlex 700 Drives - Frame 10 Components Replacement User Manual

Page 63

background image

Rockwell Automation Publication 20B-IN026B-EN-P - July 2013

63

Inverter Assembly Component Replacement Procedures

Chapter 3

Install Components

1. Mount brackets to the new Current Transducer. Torque screw to 5.6 N•m

(50 lb•in).

2. Slide Output Busbar through the Current Transducer assembly with the

angled end to the left.

3. Replace the Current Transducer assembly in mounting position by

reversing the process used in

Step 6.

of the removal process.

4. Secure the Current Transducer assembly to the heatsink with two torx

screws. Torque to 2.9 N•m (26 lb•in).

5. Reinstall the AC Output Busbar:

a. Place the AC Output Busbar onto the two existing standoff set screws.
b. Reinstall the six torx screws that secure the busbar to the IGBT

heatsink. Torque to 5.6 N•m (50 lb•in).

c. Reinstall the two standoff nuts. Torque to 5.6 N•m (50 lb•in).

6. Reinstall the Output Busbar:

a. Reinstall the set screw. Hand tighten.
b. Reinstall the torx bolt that secures the Output Busbar to the AC

Output Busbar. Torque to 9.0 N•m (80 lb•in).

c. Reinstall the two hex head bolts that secure the Output Busbar to the

U, V, or W Busbar. Torque to 5.6 N•m (50 lb•in).

d. Reinstall the standoff nut to the set screw. Torque the nut to 5.6 N•m

(50 lb•in), which will torque the set screw correctly.

7. Reconnect the wire to the Current Transducer.
8. Replace all safety shields and enclosure covers before applying power to the

drive.