WARNING!

CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL
PRIOR TO SELECTING DELAY TIME OR PWR-UP SETTINGS

101-DE

101-KDE

PWR

LOCK RED R

NO C

TRIG

REX

RESET

C NO

C NO

C NO

-

+

-

+

To

Power

Supply

TANDEM UNIT

(PAIR OF DOORS)

WHT

WHT

BLK

RED

WHT

WHT

BLK

RED

POWER

TRANSFER

HINGE

POWER

TRANSFER

HINGE

DPS

DPS

SDC 600 Series Power Supply required

**

DIP SWITCH

SETTINGS

15

30

1

2

15

20

30

1

N/C

N/O

UNLOCKED

LOCKED

VOICE/TONE

TONE
ONLY

FEMALE

MSG

MALE

MSG

O

N

DELAY

TIME

[ON]

[OFF]

1

2

3

4

5

6

7

8

NUISANCE

DELAY

REX/BYPASS

PERIOD

TRIGGER

TYPE

PWR UP

STATE

ALARM

TYPE

MESSAGE

JUMPER J1**

24VDC @ 430mA (Single)

@ 680mA (Tandem)

Monitor Relays
Contact Rating

Operating Temp

Range

Power

Requirements

SPDT (Dry)
1 Amp @12/24VDC (Resistive)

0 C to 70 C

Note:

**JUMPER J1 (DOOR PROP)

INSTALLED: The S6000DE/KDE will enter the alarm mode if the
door is held open past the request to exit period.

REMOVED: The S6000DE/KDE will remain unlocked if the door
is held open past the request to exit period. No alarm will sound.

For the S6000DE/KDE to relock and rearm upon closure of the
door, DPS is required.

Door Contact or Power Transfer Hinge by DPS required for Anti-
Tailgate and Door Prop operation.

**

**

To

Power

Supply

101-DE / 101-KDE

PWR LOCK RED ONLY

NO C

TRIG

REX

RESET

C NO

C NO

C NO

-

+

-

+

GRN ONLY

WHT

WHT

BLK

RED

POWER

TRANSFER

HINGE

SINGLE

DOOR

DPS

**

}

}

Alarm

Secure

}

}

Remote

Access

Remote

Reset

Monitor Relays

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 4