SDC S6000KDE DELAYED EGRESS DEVICE User Manual

Security door controls, Features, Code compliance

background image

SECURITY DOOR CONTROLS

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]

INSTALLATION INSTRUCTIONS

S6000DE / S6000KDE DELAYED EGRESS DEVICE

Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display

Stop Employee Theft
Stop Retail Shoplifting
Restrict Airport Patrons
Restrict Wandering Patients

The integral verbal message, digital countdown display and sign
provide comprehensive and clear instructions of the door operation
for persons without prior knowledge of the exit delay, including the
sight and hearing impaired.

The digital keypad eliminates the need to carry and locate keys for
reset and bypass functions.

Features:

Egress Delay

15 or 30 second exit delay
1 or 2 second nuisance delay

Built-In 3 Function keypad

Alarm and lock reset
1 to 30 second bypass
Sustained bypass
Additional keyswitch optional

Control Inputs

1 to 30 second request-to-exit and bypass
input with anti-tailgate and jumper
selectable door prop alarm.
Reset

Built-In Annunciation

Armed mode
Nuisance mode
Irreversible egress mode
Release mode
Digital countdown mode
Field selectable voice notification or tone
Field selectable male voice with security
message or female voice with safety
message

Monitoring Outputs

Armed mode
Egress initiation status
Released status

Trigger Modes

Egress alarm triggered by Push Bar
Trigger input from external device field
selectable (N/O or N/C)

Code Compliance

IFC International fire Code
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1 Uniform Fire Code
California Building Code
Field selectable automatic or manual power up after emergency release or power loss.
Use of manual power up complies with California Building Code (OSHPD) requirements.

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

Application:

When unauthorized egress is initiated SDC
exit Check delays egress through the door
for 15 seconds (or 30 seconds). Meanwhile,
the person exiting must wait while personnel
or security responds. The door unlocks after
15 seconds have elapsed permitting egress.
When powered by a fire control supervised
power supply, the lock will release
immediately in an emergency.

R

Choice of Mounting

Recessed mounted

(3 gang metal plaster ring included)

Surface mounted with optional 3 gang
box (DEC-J)
Optional shroud (SHD-J) to be used with
DEC-J surface box.

S6000DE

MODELS

S6000KDE

RIM MOUNT

VERTICAL ROD

MORTISE

EXIT DEVICES

NOTE: SDC 600 Series Power Supply required