Specifications – RKI Instruments Beacon 410 User Manual
Page 7

Beacon 410 Gas Monitor Operator’s Manual
Specifications • 3
Specifications
Table 1 lists specifications for the Beacon 410.
Table 1: Beacon 410 Specifications
Description
Specification
Input Power
100/115/220V ~ ±10%, 50/60Hz, 1.0/1.0/0.5A
or
24 V
± 10%, 2.5A VDC
Construction (housing)
Fiberglass/polyester with lexan window (NEMA 4X)
Dimensions
12.5 in. H x 11.0 in. W x 6.4 in. D
(31.8 cm H x 27.9 cm W x 16.3 cm D)
Weight
10.4 lbs. (without AC line cord)
Environmental Conditions
•
For indoor or outdoor locations (Type 4X)
•
2000m max. altitude
•
-20°C to 50°C (-4°F to 122°F) max. ambient
•
Maximum humidity of 80% relative
•
Mains supply voltage fluctuations not exceeding ± 10%
of nominal
•
DC supply voltage fluctuations not exceeding +10% -8%
of nominal
•
Overvoltage Category II, Pollution Degree 2
Safety/Regulatory
C US
186718
User Controls
•
Reset switch
•
Program buttons: ESCAPE, UP/YES, DOWN /NO, and
ENTER)
Relays
•
Relay contacts rated for 10A @ 115/220V~ resistive or
10A @ 30V
resistive
•
SPDT, Form C (common, normally open, and normally
closed contacts)
Standard Accessory
Operator’s manual (this document)