U64

3.3.9. Options for Telepen

Telepen is a variable length symbology with a
check digit and non printable start/stop
characters. The following characters are
supported:
• in numeric mode, the digits 00 upto 99
• in full ASCII mode, all 128 ASCII characters

The check digit calculation is derived from the
sum of all data characters modulo 127. The
check digit cannot be transmitted. For string
format see figure 3.30.

Options for Telepen:
• selection of ASCII mode

Fig. 3.30. Options for Telepen

data

(1 upto 32 characters)

Telepen

check

digit

SET

_ZZ_

Numeric mode

D2

_D2_

ASCII mode

D3

_D3_

END

_ZZ_