beautypg.com

Opticon XPT 3125 Universal menubook User Manual

Page 126

background image

Read options

5

OPTICON Universal menu book

U119

5.4. Redundancy

This is the number of times that a label must be
correctly decoded before it is transmitted.
Selecting a higher redundancy count makes
reading slower, but it reduces the probability of
reading errors, especially when labels of poor
definition are used.

SET

_ZZ_

Read 1 time,
redundancy = 0

X0

_X0_

Read 2 times,
redundancy = 1

X1

_X1_

Read 3 times,
redundancy = 2

X2

_X2_

Read 4 times,
redundancy = 3

X3

_X3_

END

_ZZ_