Opticon XPT 3125 Universal menubook User Manual
Page 119
OPTICON Universal menu book
U112
5.1. Read mode options
The following read modes are available:
Single read:
When a bar code has been decoded, the
reader will be turned OFF. The reader must be
triggered again to read another label. This
option and 'Disable trigger' can not be
programmed at the same time.
Multiple read:
When a bar code has been decoded, the
reader will stay ON for a time as set by 'Read
time options' or indefinitely if the trigger switch
has been disabled. The same label can only be
decoded again after the label has not been
detected for a number of scans.
Continuous read:
The reader will produce as much data as it can
decode regardless whether it is the same or
not. This mode is mainly used for
demonstration and diagnosis.
Disable trigger:
This is applicable to readers which have a
trigger switch. When this option is selected, the
reader will stay ON all the time.
Note: Selecting this option for a laser reader
means that the laser diode is ON continuously,
which may reduce the lifetime of this
component. Also local legislation may require
that the trigger switch is always enabled.
Therefore it is recommended not to disable the
trigger switch for laser readers.
Add-on wait mode:
Used if UPC/EAN with add-on is enabled. The
reader searches within the selected time for a
valid add-on code. If a valid add-on code is
found, the reader transmits the data
immediately. If nothing is found behind the
code, the reader will transmit the data without
add-on. If something is found behind the code,
the reader ignored the code in case it is not a
valid add-on.
Trigger repeat:
This option makes it more easy to select a
single bar code from a sheet filled with bar
codes. If the trigger switch is pressed once, the
laser beam is on during the configured read
time. The laser beam can now be moved to the
required bar code. If the trigger switch is
pressed again, the bar code is decoded and
transmitted. If the read time expires, the laser
switches off and the trigger sequence should
be repeated. If the read time is set to 0, then if
the trigger switch is pressed, the laser is on, but
does not accept bar codes. As soon the trigger
switch is released, the barcode is decoded and
transmitted. Support for this option is reader
dependent.
Structured append time out:
When a bar code consists of multiple physical
bar codes, this time out value is used. The next
bar code must be read before this time out is
expired. The time out value is between 1 and
255 seconds. This value can be configured by
reading 1 up to 3 direct input numeric
characters from chapter: String options.
Default the structured append time out is set to
30 seconds.
- PHL 5300 Universal menubook PHL 5200 Universal menubook PHL 5100 Universal menubook OPV 1001 Universal menubook OPT 6125 Universal menubook OPT 5000 Universal menubook OPT 1000 Universal menubook OPR 4001 Universal menubook OPR 3301 Universal menubook OPR 3201 Universal menubook OPR 3101 Universal menubook OPR 3004 Universal menubook OPR 3001 Universal menubook OPR 2001 Universal menubook OPN 2003 Universal menubook OPN 2002 Universal menubook OPM 2000 Universal menubook OPM 1736B Universal menubook OPL 9736 Universal menubook OPL 7836 Universal menubook OPL 7736 Universal menubook OPL 7734 Universal menubook OPL 7724 Universal menubook OPL 6845R Universal menubook OPL 6845 Universal menubook OPL 6835 Universal menubook OPL 6735 Universal menubook OPL 5850 Universal menubook OPL 2724 Universal menubook OPI 4012 Universal menubook OPI 4002 Universal menubook OPI 2201 Universal menubook OPI 2002 Universal menubook OPD 7435 Universal menubook OPD 7124 Universal menubook NLV 2101 NLV 2001 NLV 1001 NFT 7345 NFT 7175 NFT 1195 NFT 1175 NFT 2100 NFD 1267 MSH 220 wedge LMD 1135 H19 Universal menubook H16 Universal menubook Universal menubook С-37 Universal menubook