MAGNA-LOC
VeNted rIdGe wItH z-CLOsure
INstALLAtION NOtes
Magna-Loc Eave Plate and Magna-Loc panels must be installed prior to Vented Ridge installation (see pages 43-53).
1. Once panels have been installed, slide Back-Up Channel under upper edge of panels. Position Back-Up Channel to allow
for proper installation of vented ridge assembly. Use C-clamps to hold Back-Up Channel in place.
2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 0"-2" from panel end on
both sides of ridge.
3. Install Magna-Loc End Dams over Tape Sealant. Before continuing make sure End Dam placement will accommodate
Vented Ridge Cover.
4. Once closure is set in Tape Sealant, fasten through End Dam, Tape Sealant, Magna-Loc panel, and into Back-Up Channel
with (5) #12-14 x 1" SD N/W per panel. C-clamps may be removed once Closures have been fastened.
5. Once all End Dams have been installed, place a row of Double Bead Tape Sealant across top of End Dams on both sides of
ridge. Tube Sealant must be used to fill any and all gaps left around End Dams.
6. Install Vent Drip, Vent Material, and Offset Cleat (in order) and fasten to top leg of End Dam with #14 Dekfasts at 1'-0"o.c.
7. Apply a row of Double Bead Tape Sealant across outer leg of Offset Cleat.
8. Install Vented Ridge Cover and secure to outer leg of Offset Cleat with Pop Rivets at 1'-0"o.c.
9. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.
Double Bead Tape Sealant
#12-14 x 1" SD NW
Magna-Loc End Dam
Magna-Loc Panel
Foating Clip
Magna-Loc Eave Plate
#10-12 x 1" PHW (1'-0" o.c.)
Vented Ridge Cover
1
/
8
" x
3
/
16
" Pop Rivet (1'-0" o.c.)
#14 x 2" Dekfast (1'-0" o.c.)
Offset Cleat
Vent Material
Vent Drip
2" MIN
CL
#12-14 x 1" SD NW
1
3
2
5
4
FASTENING PATTERN
1
/
2
:12 slope
Minimum