Step 5, Magna-loc, Installation of panel – Metal Sales Magna-Loc Installation User Manual
Page 47
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
47
MAGNA-LOC
Magna-Loc Eave Panel
Cee Clamp
Magna-Loc
Peak Panel
Pull up center of panel
Endlap Purlin
Endlap
Pad
Note: It is critical that purlins at the ridge and endlap be exactly located as detailed on erection
drawings in order for panels to have adequate movement due to thermal expansion and contraction.
Panels with endlaps must be fixed at the eave and endlap splices are to be installed inline along the
same purlin. The following procedures also apply to panel runs with multiple laps.
ENDLAPPING OF PANEL
Endlap Purlins
Peak
Eave
1
2 4 6 8
3 5 7
In-line
Endlapping
8"
Endlap
Purlin
Magna-Loc
Panel
INSTALLING
PANEL CLIP
STEP
5
Magna-Loc Peak Panel
End of factory notch
Magna-Loc
Eave Panel
Endlap Pad
Endlap Purlin
INSTALLATION OF PANEL (
cont
.)
Steps:
1. The eave panel when installed should measure 8" from the web of the endlap purlin to the end of the eave panel. This
dimension must be verified. If the panel extends past the web of the endlap purlin by 8", verify that the eave overhang
dimension is correct.
2. The male and female legs of the high end of the eave panel are factory notched 2" to allow the peak panel to nest inside
the eave panel.
3. Slide Back-up Channel under panel in center of endlap and cee clamp to panel to hold in place for attachment.
4. Apply Endlap Pad on the notched end of the eave panel down male leg, across panel flat, and up the female leg ½" to ¾"
from the end of the panel.
5. Lap the female leg of the peak panel into the female leg of the eave panel lapping the proper 2".
6. Hold the flat of the peak panel up and nest the male legs together.