Magna-loc, Storage – Metal Sales Magna-Loc Installation User Manual
Page 35
![background image](/manuals/567690/35/background.png)
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
35
MAGNA-LOC
To facilitate the handling of Magna-Loc panels, panel bundles can be lifted and placed on the roof. Bundles need to be placed
on the roof in order for the roof structure to handle the weight. Loading capabilities of the structure must be checked.
When lifting packaged sheets, make certain they are adequately supported. Panels less than 20'-0" in length can normally be
lifted with a forklift; however, when lifting panels in excess of 20'-0", it is recommended that a spreader bar and slings be
used. As a rule, when lifting, no more than
1
/
3
of the length of the panel should be left unsupported.
Make a plan for bundle placement by determining how much area a bundle of panels will cover. Bundles should be placed on
the roof in accordance with the direction the panel will be installed. Consider where the string line, if any, is to run at the eave
to set roof panels by. Roof bundles should not interfere with this string line.
STORAGE (
cont
.)
STORAGE ON ROOF
Spacer Bar
Magna-Loc
Panels
Open Framing
Wood Blocking
Rigid Frame