Magna-loc, Ssr sculpt. rake – Metal Sales Magna-Loc Installation User Manual
Page 59
![background image](/manuals/567690/59/background.png)
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
59
MAGNA-LOC
ssr sCuLpt. rAKe (
on
module
)
INstALLAtION NOtes
Magna-Loc floating rake zee and Magna-Loc panels must be installed prior to SSR Sculptured Rake installation (See
pages 43-53).
1. With Magna-Loc panel properly nested over top of Magna-Loc Floating Rake Zee, apply a row of Double Bead Tape
Sealant across upper side of panel rib.
2. Install SSR Rake Cleat over Double Bead Tape Sealant. Fasten through SSR Rake Cleat, Tape Sealant, panel, and into
Floating Rake Zee with #12-14 x 1
1
/
4
" Self Driller XL screws, 1'-0"o.c.
3. Apply a row of Double Bead Tape Sealant across top leg of SSR Rake Cleat.
4. Install SSR Sculptured Rake flashing so that top of flashing is flush with top of SSR Rake Cleat and panel rib. Fasten
through SSR Sculptured Rake, Tape Sealant, and into SSR Rake Cleat with ¼"-14 x
7
/
8
" Stitch XL, 1'-0"o.c.
5. Position and apply a row of Double Bead Tape Sealant across wall panel just below lower leg of SSR Rake Flashing.
6. Install SSR Rake Slide over lower leg of SSR Rake flashing and Double Bead Tape Sealant. Fasten with ¼"-14 x
7
/
8
"
Stitch XL, 1'-0"o.c.
7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.
Magna-Loc Panel
Rake Angle (by others)
1
/
4
"-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
SSR Sculptured Rake (off module)
Double Bead Tape Sealant
Floating Rake Zee
#12-14 x 1
1
/
4
" SD XL (1'-0" o.c.)
1
/
4
"-14 x 1
1
/
4
" Shoulder SD (1'-0" o.c.)
SSR Rake Slide
1
/
4
"-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
Double Bead Tape Sealant
SSR Rake Cleat
1
/
2
:12 slope
Minimum