Magna-loc, Endlap over open framing – Metal Sales Magna-Loc Installation User Manual
Page 58
![background image](/manuals/567690/58/background.png)
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
MAGNA-LOC
58
eNdLAp OVer OpeN FrAMING
INstALLAtION NOtes
1. Once eave panel has been installed, (see page 47), slide a Back-Up Channel under upper edge of panels. Back-Up
Channel should be flush with edge of Magna-Loc eave panel. Use C-clamps to hold Back-Up Channel in place.
2. Apply a row of Endlap Pads across flat pans, up and over all ribs of eave panels. Endlap Pad should be flush with edge of
eave panel.
3. Roll Magna-Loc peak panel into place and nest with eave panel so that 2" factory notch is completely covered. (See page
47 for complete details on installing lapped panels.)
4. With peak panel in place, fasten panel endlap with (5) #12-14 x 1
1
/
4
" SD XL fasteners per panel through factory punched
holes and into the Back-Up Channel.
5. Apply a pig tail of Endlap Pad, approximately 2½", over factory notched section of male legs.
Magna-Loc Peak Panel (factory pre-punched)
2" (Panel Notch)
Endlap Pad
#12-14 x 1
1
/
4
" SD XL (see below)
Magna-Loc Eave Panel (factory notch)
Back-up Channel
Pigtail of Endlap Pad
#12-14 x 1
1
/
4
" SD XL
1
3
2
5
4
FASTENING PATTERN
8"
1
/
2
:12 slope
Minimum