Magna-loc, Rakewall (off module) – Metal Sales Magna-Loc Installation User Manual
Page 62
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
MAGNA-LOC
62
rAKewALL (OFF MOduLe)
INstALLAtION NOtes
Magna-Loc Floating Rake Zee and Magna-Loc Panels must be installed prior to Rakewall installation
(See pages 43-53).
1. With Magna-Loc panel nested against Magna-Loc Floating Rake Zee, apply a row of Double Bead Tape Sealant across
upper side of field bent panel rib. (See page 51 for proper bending of panel.)
2. Install SSR Rake Cleat over Double Bead Tape Sealant. Fasten through SSR Rake Cleat, tape sealant, panel, and into
floating rake zee with #12-14 x 1
1
/
4
" Self Driller XL screws, 1'-0"o.c.
3. Apply a row of Double Bead Tape Sealant across top leg of SSR Rake Cleat.
4. Install SSR Rakewall so that top of flashing is flush with top of SSR Rake Cleat and panel rib. Fasten through SSR
Rakewall, tape sealant, and into SSR Rake Cleat with ¼"-14 x
7
/
8
" Stitch XL, 1'-0"o.c.
5. Install Counter Flashing, Reglet, or wall panel and fasten to parapet wall with appropriate fastener, 12"o.c. If Counter
Flashing or Reglet is used, seal to parapet wall with tube sealant. Do NOT fasten SSR Rakewall to parapet wall.
6. If two or more flashings are required, lap the flashing over the previously installed flashing by a min. of 2" placing a bead
of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.
1
7
/
8
"
Rake Angle (by others)
1
/
4
"-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
SSR Rakewall
Double Bead Tape Sealant
SSR Rake Cleat
Floating Rake Zee
Magna-Loc Panel (field cut and bend)
Tube Sealant
#12-14 x 1
1
/
4
" SD XL (1'-0" o.c.)
1
/
4
"-14 x 1
1
/
4
" Shoulder SD (1'-0" o.c.)
Reglet Flashing
1
/
2
:12 slope
Minimum