Magna-loc, 9" drop valley over open framing – Metal Sales Magna-Loc Installation User Manual
Page 57
![background image](/manuals/567690/57/background.png)
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
57
MAGNA-LOC
9" drOp VALLey OVer OpeN FrAMING
3:12 slope
Minimum
INstALLAtION NOtes
All Valley flashings must be installed prior to panel installation. If two or more Valley flashings are required, valley
must be installed working from eave to peak. It is recommeneded that ice and water shield be installed under Valley
flashing for added moisture protection.
1. Install Drop Valley flashing back against previously installed Eave Plates, (see page 44). To hold Sculptured Eave in
place fasten to substrate with #10-16 x 1" Pancake Head fastener, 4'-0"o.c. into top leg of Eave Plate.
2. Apply a row of Double Bead Tape Sealant across both sides of the Drop Valley flashing so that the sealant is centered over
the top leg of the Eave Plate.
3. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 6" placing
two beads of Tube Sealant per side between the flashings.
4. Once panels have been installed and properly sealed, (see page 45), fasten through panel, Double Bead Tape Sealant, and
Drop Valley into Eave Plate with #12-14 x 1
1
/
4
" Self Driller XL screws.
Magna-Loc Panel (field cut)
(2) Rows of Tube Sealant (between panel ribs)
Double Bead Tape Sealant
SSR 9" Drop Valley
Eave Plate
#12-14 x 1" SD N/W (1'-0" o.c.)
#12-14 x 1
1
/
4
" SD XL (see page 45)
Valley Plate (by others)