Magna-loc, Sculptured eave over open framing – Metal Sales Magna-Loc Installation User Manual
Page 54
© Metal Sales Manufacturing Corporation / Subject to change without notice 6/12
MAGNA-LOC
54
sCuLptured eAVe OVer OpeN FrAMING
1
/
4
"-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
Double Bead Tape Sealant
Fastener (by others)
Magna-Loc Panel
1
3
/
8
"
INstALLAtION NOtes
All Eave flashings must be installed prior to panel installation.
1. Install Sculptured Eave back against previously installed Eave Plate, (see page 44 for Eave Plate installation). To hold
Sculptured Eave in place fasten to substrate with #10-16 x 1" Pancake Head fastener, 4'-0"o.c.
2. Fasten Sculptured Eave to wall with appropriate fastener, 12" o.c.
3. Apply a row of Double Bead Tape Sealant across Sculptured Eave so that sealant is centered over top leg of Eave Plate.
4. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with Pop Rivets, 2.5"o.c.
5. Once panels have been installed and properly sealed, (See page 45), fasten through panel, Double Bead Tape Sealant, and
Sculptured Eave into Eave Plate with (5) #12-14 x 1
1
/
4
" Self Driller XL screws per panel.
Tube Sealant
Double Bead Tape Sealant
Magna-Loc Sculptured Eave
Wall Panel
Eave Plate
#12-14 x 1" SD N/W (1'-0" o.c.)
#12-14 x 1
1
/
4
" SD XL (see below)
#12-14 x 1
1
/
4
" SD XL
1
3
2
5
4
FASTENING PATTERN
Wall Closure (by others)
1
/
2
:12 slope
Minimum