beautypg.com

6 appendix – JUMO 707050 dTRANS T05 - Programmable 2-Wire Transmitter Operating Manual User Manual

Page 67

background image

29

6 Appendix

Thermocouples

Resistance transmitter and resistor/potentiometer

Designation

Type Standard

ITS

Measuring
range
in °C

Measuring accu-
racy

a

Min.

Max.

Pt13Rh-Pt

R

IEC 584-1

ITS-90

-50

1768

± 0.15 % from
+50 °C

Pt10Rh-Pt

S

IEC 584-1

ITS-90

-50

1768

± 0.15 % from
+20 °C

Pt30Rh-Pt6Rh

B

IEC 584-1

ITS-90

0

1820

± 0.15 % from
+400 °C

Fe-CuNi

J

IEC 584-1

ITS-90

-210

1200

± 0.1 % from -100 °C

Cu-CuNi

T

IEC 584-1

ITS-90

-270

400

± 0.1 % from -150 °C

NiCr-CuNi

E

IEC 584-1

ITS-90

-270

1000

± 0.1 % from -80 °C

NiCr-Ni

K

IEC 584-1

ITS-90

-270

1372

± 0.1 % from -80 °C

NiCrSi-NiSi

N

IEC 584-1

ITS-90

-270

1300

± 0.1 % from -80 °C

Fe-CuNi

L

DIN 43710

IPTS-
68

-200

900

 0.1 %

Cu-CuNi

U

DIN 43710

IPTS-
68

-200

600

± 0.1 % from -100 °C

Chromel-Copel (Ni9.5Cr-
Cu44Ni)

L

GOST R 8.585-2001

ITS-90

-200

800

± 0.1 % from -80 °C

Chromel-Alumel

GOST R 8.585-2001

ITS-90

-270

1372

± 0.1 % from -80 °C

W5Re-W20Re

A1

GOST R 8.585-2001

ITS-90

0

2500

± 0.15 %

W5Re-W26Re

C

ASTM E230/E230M-11

ITS-90

0

2315

± 0.15 %

W3Re-W25Re

D

ASTM E1751/E1751M-
09

ITS-90

0

2315

± 0.25 %

PL II (Platinel

b

II)

ASTM E1751/E1751M-
09

ITS-90

0

1395

± 0.15 %

Cold junction

Pt1000 internal or external cold junction; temperature adjustable 0 to 80 °C

Cold junction accuracy

± 1 K

a

The accuracy values refer to the complete measuring range.

b

Platinel is a registered trademark of Engelhardt Corp.

Designation

Measuring range

Measuring accuracy

Resistance transmitter

Up to 10000

±10

Resistor/potentiometer

 400 

400 m

 400  to  4000 

 4 

 4000  to  10000 

10 