17

4 Electrical connection

4.3

Terminal assignment and dimensions (mm) of
dTRANS T05 T

101.2

102.5

6.2

93.1

A

B

A 5:1

B 5:1

This figure shows type 707051 installed on a TH 35-7.5 DIN rail. The specifications concerning dimensions are
only valid for installation on this DIN rail and change accordingly if a TH 35-15 DIN rail is used.

Connection for

Terminal assignment

Voltage supply

Type 707051

R

B

= (V

b

- 11 V)/22 mA

DC 11 to 35 V

Current output

R

B

= Load resistance

4 to 20 mA

V

b

= Voltage supply

Voltage output

0 to 10 V

Analog inputs

RTD temperature probe

R

L

 11 

2-wire circuit

R

L

= Lead wire resistance per wire

RTD temperature probe

R

L

 11 

3-wire circuit (3W)

R

L

= Lead wire resistance per wire

RTD temperature probe

R

L

 11 

4-wire circuit (4W)

R

L

= Lead wire resistance per wire

2

1

+

4

3

+

6

7

8

5

J

J

6

7

8

5

J

6

7

8

5