Install drd rack door, Install semi-recessed finished cover, Drd semi-recessed installation kit – ETC Unison DRd Semi-Recessed Installation Kit User Manual
Page 8
![background image](/manuals/559202/8/background.png)
E T C I n s t a l l a t i o n G u i d e
DRd Semi-Recessed Installation Kit
DRd Semi-Recessed Installation Kit Installation Guide
Page 8 of 8
Electronic Theatre Controls, Inc.
Install DRd Rack Door
Step 2:
Install the top and bottom screws.
Step 3:
Re-attach ground spade to its receptacle on the rack door.
Install Semi-Recessed Finished Cover
The finished cover for this installation kit simply installs over the DRd rack, securing with screws directly
to the rough-in enclosure or the extension rails, if they are used.
N o t e :
The DRd enclosure and rack door are provided with magnets that help maintain the
door in a closed position during unlocked operation. DO NOT rely on this magnet to
hold the door when it is unassisted and unattached.
N o t e :
Before attaching the cover, notice that its is provided with a removable panel located
on the lower right hand corner. Remove this panel (similar to a knockout) ONLY if the
DRd rack is installed with a Unison Battery Pack (UBPO).
Use whichever sequence you prefer to
re-attach the DRd rack door to the enclosure,
ensuring the top screw and bottom screw, as
well as the ground spade are re-installed.
The following sequence has proven to be
successful.
Step 1:
Align the door to the enclosure
in the closed position. The top
and bottom hinge brackets
should be aligned over the
screw holes.
Attach the cover using the eight 10-32 screws provided.