E T C I n s t a l l a t i o n G u i d e

DRd Semi-Recessed Installation Kit

DRd Semi-Recessed Installation Kit Installation Guide

Page 6 of 8

Electronic Theatre Controls, Inc.

Install DRd Rack Enclosure

Step 4:

Secure the DRd rack into place using four 5/16” nuts and washers provided. Tighten the
hardware securely.

Complete DRd Rack Installation

Refer to the Unison DRd Rack Enclosure Installation Manual, to complete the DRd rack installation.

Step 1:

Remove the DRd rack enclosure

door before installing the DRd into

the recessed enclosure.

• Open the rack door and

separate the ground cable
between the rack and the door
by pulling the faston tab free.

• Remove the screw securing

the bottom of the rack.

• Remove the screw securing

the top of the rack and the
door should be free.

Step 2:

Store the rack door and hardware
in a safe location until final
installation.

Step 3:

Insert the DRd rack into the recessed enclosure.

a: Angle the DRd rack top side first into the recessed

enclosure first, clearing the fan grill and any conduit

fittings (if any).

b: Then rest the bottom edge of the DRd on the small

ledge that is provided on the back pane of the
enclosure. The keyholes on the rear panel of the
DRd should align to the threaded studs on the
recessed enclosure.