Object 0x2004: ecam data, Object 0x2004: ecam data -3, 0x2004 – ElmoMC CANopen DS 301 Implementation Guide User Manual
Page 80: Fast, Simpliq

Notes:
The transmission type for mapping this object must be 255; otherwise, an Abort
message (code 0604 0043h) will be transmitted.
When this object is used to feed PT reference points to the drive while a PT
motion is executing, the drive automatically enters Online Feed mode, in which
the drive is aware of the position written and takes the following precautions:
If the feed is too slow, the drive needs to fetch points not yet programmed,
and the motion will abort with a “Queue underflow” emergency.
If the feed is too fast, so that points not yet used are overstruck, the drive will
reject the feed attempt with a “Queue overflow” emergency.
The Online Feed mode will continue until at least one setting of PT parameters
has been completed without using the RPDO.
Object 0x2004: ECAM data
This object sets ECAM data for the ECAM table entries.
Object description:
Index 2004h
Name ECAM
data
Object code
VAR
Data type
PT DataPar (object 0x41)
Category Optional
Entry description:
Access Write
only
PDO mapping
Yes
Value range
No
Default value
No
Notes:
The transmission type for mapping this object must be 255; otherwise, an Abort
message (code 0604 0043h) will be transmitted.
When this object is used to feed ECAM reference points to the drive, a working
table with a border cannot be used. (Refer to the
SimplIQ
Software Reference
Manual for more information.)
CANopen DS 301 Implementation Guide
Manufacturer-specific Objects
MAN-CAN301IG (Ver. 2.1)
13-3